Cavity wall tie surveys require more than a boroscope – some diligence and integrity is required!

I was called to a property in the roundhay area of Leeds a few weeks back. The very large detached house is divided into three flats, each quite large in itself.  One of the flat owners was in the process of buying a second apartment from an existing neighbour.

The large detached house, with Mock Tudor style upper

Their transaction stalled when a survey revealed cavity wall tie corrosion as a problem. The property has almost 200M2 of wall surface, over three floors, so the quotation, from a Bradford based wall tie specialist firm was very high; in effect, with the current mortgage climate; it scuppered the deal. All involved were disappointed.

However, on looking at the specialist report, the local estate agent was perplexed; the wall tie surveyor’s findings appeared to be based solely on the appearance of horizontal cracks in the ‘Mock Tudor’ render at first floor level.  The cracks were evenly spaced and ‘tramline’ just like wall tie corrosion expansion cracks are.

A clear pattern of horizontal cracks can be a sign on wall tie corrosion.

Wall Tie Corrosion? We'll see

I was asked to attend and give my opinion.  What I found demonstrates the importance of backing up assumptions with facts and being diligent on surveys; especially where customers are basing home purchase and sales on the findings. Only parts of the property were rendered and the regular horizontal cracking was confined to these areas only.  Odd that; why only the render?  Why not in the adjacent cavity brickwork?

The building is Pre-war; about the time that pitch coating was being phased out and galvanising becoming more mainstream.

 

A wall tie corrosion survey in Yorkshire with inspection at high and low level

The yellow circle indicates the galvanised tie location - the red indicates the pitch coated fishtail tie

A quick borescope inspection revealed ties of two types: Well galvanised fishtails and formerly pitch coated fishtails (see images).

As can be seen, the galvanised ties had aged well, whereas the pitch coated ones were very rusty – this in quite normal.

This cavity wall ties survey reveals no wall tie corrosion

The galvanised tie, with very slight corrosion

 

This cavity wall tie is very severely corroded

The corroding fishtail wall tie seen via my Boroscope

However, scanning the Mock Tudor render revealed no evidence of wall ties. So I drilled random holes over three elevations, through the render and into the brick behind.  This was clearly a solid wall with no metal wall ties. The only metallic objects I could find corresponded to the fixings in the Tudor joinery. So with permission, we removed a piece and exposed the wall behind.

The Tudor joinery was fixed at regular intervals to timber plates bedded into the brickwork, the horizontal cracks were merely an indication of the slight differential movement at the interface between the render on brick and the render on timber – not a structural problem.

Close-up of the wall behind the Tudor joinery

The wall plates have been placed as fixing points for the Mock Tudor joinery.

The render area is over half the total area of the house and some of the areas which are not rendered are solid wall. This reduced the extent of work by 70% and now the sale is back on.

 

Conclusions?

  1. Horizontal cracking is an indicator of wall tie corrosion. However, indications are not normally enough and should be backed up with further investigations, taking all relevant factors into account.
  2. Ideally photographic evidence of the condition of the wall ties should be asked for.
  3. The report should include at least some methodology, indicating the construction of the walls, the type of wall ties installed and their condition, using BRE401 as a reference.

Dry Rot.

 

Copyright © 2010 Preservation Expert. Legal Stuff: All the advice and information in the posts on my blog is made in good faith and is based on my experience and knowledge at the time of writing. However, nobody is infallible and whilst I’m confident that most of what I write about preservation issues is accurate, there’s a good chance there’ll be an error or two somewhere. I do change my mind about stuff, as I gain more experience. In view of this you must make your own decisions on whether to follow any advice I write and think about this; I could be wrong. No responsibility will be accepted by the author for any losses anyone may suffer as a result of any mistake or for the consequence of any action you take as a result of reading this blog. If you do suffer a loss, resulting from anything I’ve written, a verbal heartfelt apology will be your only compensation.